CXGPM Intelligent Inverter Circulation Pump

  • Detail
  • Parameters
Model
CXGPM
Flow rate Q
3~12m³/h
Lift H
4~20m
Working pressure
≤1MPa
Single motor power of the moto
22~360W
Ambient temperature
0°C~40°C
Protection class
IP42
Conveyed medium
Clean water that is free of particles, mineral - o
Operating temperature
+2°C~+110°C
Home
Customer service
Tel
Contact Us
自由容器
CXGPM Intelligent Inverter Circulation Pump Focused on small-to-medium heating and hot water circulation scenarios, the CXGPM intelligent inverter circulation pump shares core technologies with the same-brand GPS series. However, it places greater emphasis on "medium-to-high demand scenarios" in terms of flow rate, lift coverage, and installation adaptability. Equipped with a built-in AUTO adaptive control function, the pump automatically stores parameters after a power outage and requires no reconfiguration when power is restored, making it suitable for operation by non-professional users. Its overall design centers on "intelligence, durability, and wide scenario adaptability", and it is particularly well-suited for heating and hot water circulation scenarios with slightly higher flow rate requirements.
自由容器-副本5
Application
Domestic Medium-to-Large Heating Systems (Underfloor Heating/Double-Pipe Radiators)
Suitable for residences with an area of 100~200㎡ (e.g., three-bedroom two-living-room apartments, first floor of villas). The AUTO adaptive function can automatically adjust the flow rate and lift according to the indoor-outdoor temperature difference and the heating demand of rooms. For example, in winter, when there are many people indoors during the day and the temperature demand is high, the pump automatically increases its power; at night, the optional "automatic night speed reduction" function can be activated, reducing energy consumption by 20%~30 while avoiding balance valve noise. It is particularly suitable for double-pipe heating systems, as it can accurately match the differences in heat demand between rooms and reduce the problem of "uneven heating and cooling".
Domestic Domestic Hot Water Recirculation Systems (Multi-Bathroom Scenarios)
Used for hot water circulation of gas/electric water heaters in residences with multiple bathrooms (e.g., villas, duplex buildings). Through frequency conversion adjustment, it ensures stable water temperature in the hot water pipes of each bathroom (e.g., maintaining 40~50℃), so that hot water flows out immediately when the faucet is turned on, avoiding the need to wait for cold water to drain when using water across floors. With a medium temperature range of 2~110℃, it can adapt to the high-temperature hot water output by water heaters (≤70℃). Moreover, its energy-saving feature can reduce the energy consumption caused by repeated heating of the water heater, lowering the total domestic electricity consumption.
Small-to-Medium Commercial Heating/Hot Water Systems
Applicable to heating and hot water circulation in guesthouses (10~20 rooms), small hotels (fewer than 30 rooms), and office buildings (1000~2000㎡). Medium-to-high flow models (e.g., GPM25-12-130 with a flow rate of 7.6 m³/h) can meet the demand for simultaneous water use by multiple users. The proportional pressure difference control function can avoid excessively high lift caused by changes in system resistance, reduce balance valve noise, and improve the quietness of commercial spaces. With an IP42 protection rating, it is suitable for humid environments such as boiler rooms and bathrooms, requiring no additional protection.
自由容器-副本4
Features
AUTO Adaptive Control + Multiple Control Modes, High Intelligence
AUTO Adaptive Mode (Factory Default)
: No manual debugging is required. The pump automatically learns system characteristics and optimizes to the optimal operating state within 1-2 weeks, adapting to mainstream systems such as underfloor heating and double-pipe heating. Parameters are automatically saved after power outage, and no reconfiguration is needed when power is restored, making it suitable for non-professional users.
Flexible Switching Between Multiple Modes: It supports 3 proportional pressure difference curves (PP1~PP3), 3 constant pressure curves (CP1~CP3), and 3 fixed-speed curves (S1~S3), which can be selected according to system types. For example, PP mode (adjusting pressure with flow changes) is used for underfloor heating, and CP mode (maintaining constant pressure) is used for hot water circulation, adapting to control needs of different scenarios.
Automatic Night Speed Reduction: Optional function. It judges the night period through a built-in pipeline temperature sensor (when the pipeline temperature stays at 10~15℃ for 2 hours and the cooling rate is ≥0.1℃/min), then automatically reduces the rotation speed. This ensures basic heating/hot water needs are not affected while achieving further energy savings.
Medium-to-High Flow Rate + Wide Temperature Range, Wide Scene Coverage
Comprehensive Flow Rate and Lift Coverage: With a flow rate of 3~7.6 m³/h and a lift of 4~12 m, it covers needs ranging from "heating for small-to-medium apartments" to "small-to-medium commercial circulation". For instance, the GPM20 series is suitable for residences under 100㎡, while the GPM25-12 series is suitable for residences over 200㎡ or small guesthouses.
Medium Temperature Range: 2~110℃: It can transport cold water (air conditioning circulating water), warm water (domestic hot water), and medium-temperature liquids (heating hot water). Compared with conventional pumps (5~50℃), its applicable scenarios are expanded by more than double. One device can replace the combination of "heating pump + hot water circulation pump", reducing equipment investment.
System Pressure: 1.0MPa: It adapts to water circulation needs of 2~4-story buildings (such as multi-story guesthouses and office buildings). The inlet pressure is reasonably designed (e.g., minimum inlet pressure of 0.108MPa at 110℃), avoiding cavitation noise and bearing damage, and ensuring stable water supply for high floors.
Parameters
ModelFlow Rate(m³/h)Head(m)Power (W)
GPM20-4-1303422
GPM20-5-1303.4532
GPM20-6-1303.7638
GPM25-4-1303422
GPM25-5-1303.4532
GPM25-6-1303.7638
GPM25-8-1305.8880
GPM25-10-1306.810120
GPM25-12-1307.612180
GPM25-4-1803422
GPM25-5-1803.4532
GPM25-6-1803.7638
GPM25-8-1805.8880
GPM25-10-1806.810120
GPM25-12-1807.612180
GPM32-4-1803422
GPM32-5-1803.4532
GPM32-6-1803.7638
GPM32-8-1805.8880
GPM32-10-1806.810120
GPM32-12-1807.612180
GPM25-18-18010.518280
GPM25-20-1801220360
GPM32-18-18010.518280
GPM32-20-1801220360

Note: The relevant data is for reference only. For updated product parameters,please contact our customer service.