Features
AUTO Adaptive Control + Multiple Control Modes, High Intelligence
AUTO Adaptive Mode (Factory Default)
: No manual debugging is required. The pump automatically learns system characteristics and optimizes to the optimal operating state within 1-2 weeks, adapting to mainstream systems such as underfloor heating and double-pipe heating. Parameters are automatically saved after power outage, and no reconfiguration is needed when power is restored, making it suitable for non-professional users.
Flexible Switching Between Multiple Modes: It supports 3 proportional pressure difference curves (PP1~PP3), 3 constant pressure curves (CP1~CP3), and 3 fixed-speed curves (S1~S3), which can be selected according to system types. For example, PP mode (adjusting pressure with flow changes) is used for underfloor heating, and CP mode (maintaining constant pressure) is used for hot water circulation, adapting to control needs of different scenarios.
Automatic Night Speed Reduction: Optional function. It judges the night period through a built-in pipeline temperature sensor (when the pipeline temperature stays at 10~15℃ for 2 hours and the cooling rate is ≥0.1℃/min), then automatically reduces the rotation speed. This ensures basic heating/hot water needs are not affected while achieving further energy savings.
Medium-to-High Flow Rate + Wide Temperature Range, Wide Scene Coverage
Comprehensive Flow Rate and Lift Coverage: With a flow rate of 3~7.6 m³/h and a lift of 4~12 m, it covers needs ranging from "heating for small-to-medium apartments" to "small-to-medium commercial circulation". For instance, the GPM20 series is suitable for residences under 100㎡, while the GPM25-12 series is suitable for residences over 200㎡ or small guesthouses.
Medium Temperature Range: 2~110℃: It can transport cold water (air conditioning circulating water), warm water (domestic hot water), and medium-temperature liquids (heating hot water). Compared with conventional pumps (5~50℃), its applicable scenarios are expanded by more than double. One device can replace the combination of "heating pump + hot water circulation pump", reducing equipment investment.
System Pressure: 1.0MPa: It adapts to water circulation needs of 2~4-story buildings (such as multi-story guesthouses and office buildings). The inlet pressure is reasonably designed (e.g., minimum inlet pressure of 0.108MPa at 110℃), avoiding cavitation noise and bearing damage, and ensuring stable water supply for high floors.